These are interlocked block solutions arranged to meet accomodation, food and sleeping place, toilet and shower requirements of large number of workers and technical personel in the same worksite.

Many container roof constructions are interlocked with corridor systems, stairs and stairheads optionally. Multiple containers are based on interlocking containers of various sizes and numbers side by side or on top of each other, therefore constituting reliable and comfortable spaces to serve many people at the same time. It could be disassembled and stored when there is no continuing need for the building or could be re-modulated to be used again for new requirements.





Technical Specifications

Snow load

80 kg/m2 - TS 498 and TS EN 1991-1-3

Wind speed

102 km/hour (50 Kg / m2) TS 498 and TS EN 1991-1-4

Exterior wall heat transfer coefficient

K: 0,37 Kcal / m2 hC ( K: 0,43 W / m2 K )

Interior wall heat transfer coefficient

K: 0,36 Kcal / m2 Hc ( K: 0,42 W / m2 K )

Roof heat transfer coefficient

K: 0,39 Kcal / m2 hC ( K: 0,45 W / m2 K )

Frame load capacity

200 kg/m2 (for two-storey buildings) T.S 498 (Could be 200/350/500 kg/m2 in respect of utilization purpose and kind according to T.S. 498)

Earthquake zone

Effective ground acceleration coefficient :Ao=0,40 (1.degree earthquake zone )
Building Importance Coefficient (I=1)
Moving Load Participation Coefficient (n=0,3,I=1/1,2/1,4/1,5) should be calculated as n=0,3 / 0,6 according to building purpose and type of use.

RELATED STANDARDS

DESIGN-STATIC: TS EN 1993-1-1, 1-2, 1-8+AC, (EUROCODE 3), TS11372, TS498,TS648, TS 6793, TS EN 1991-1-1-3, 1-1-4 (EUROCODE 1), TS EN 1998-1 (EUROCODE 8),
IMO-01.R-01/2005, Regulation Regarding Buildings to be Built in Earthquake Zones-2007
PANEL CARCASSES, TRUSS, PURLIN STEEL CONSTRUCTION :
Material:
DX51D+Z (~St 37) Erdemir quality no 1311, S250GD+Z Erdemir quality no 1325,
S320GD+Z Erdemir quality No 1332 , S350GD+Z (~St 52) Erdemir Quality No 1335,
standard DIN EN 10346-00, building steel galvanized by zinc coating
Production: Galvanized C / U sectioned cold formed profile compatible to JIT production
system in TS EN 10162 standards and extruded from rollformer machine,
in 0,8-2 mm steel sheet thickness and 40-300 mm web width.
Juncture components : Clinch nut, galvanized bolt, nut DIN 960-961,DIN 935-F,8.8
Heat Insulation : Regulation of Heat Insulation (8.05.2000)
Sound Insulation : TS 187 and TS 854 (DIN 4109)
Fire Resistance : TS 1263, DIN 4102, TS EN 13501-1, Regulation Regarding Protection of
Buildings from Fire – 2002

Climate Region

Wall insulation compatible for 3rd climate region ( K:0,50 W / m2 K ).
Roof insulation compatible for 1st ~ 2nd climate region ( K:0,40 W / m2 K )