Technical Specifications
PLAN : Pre-manufactured light prefabricated steel structure, width: 10 m (single span), Length: 250/300 cm or at rates of, column height: 4-5-6 m. Building height can be extended as desired rate of 250 cm or 300 cm. Block width to be 10 m, can be made double, triple, four or five blocks. All architectural plannings, designs and technical drawings are made with ARCHICAD 9 TR, STRUCAD (Structural Steel Detailing System Version-16) and Autocad, STA4CAD, ÇELİKPROIV softwares, engineering calculations are made with SAP 2000, CFS software by our technical staff. All material used are TSE certified.
Snow load
|
80 kg / m² (at the installation location of the snow and varies according to altitude) TS 498 and TS7046.
|
Wind speed
|
102 km / h (50 kg / m 2) (h: up to 0-8 m) TS 498.
|
Heat transmission coefficient
|
No insulation material.
|
Earthquake Zone
|
Effective ground acceleration coefficient Ao = 0.40 (1st degree earthquake zone), Building Importance Factor
(I = 1)
Live Load Participation Factor (n = 0,3). Climate Zone types are insulated manufacturing any climate zone can be taken into consideration.
|
RELATED STANDARDS
|
DESIGN-STATIC: EUROCODE 3,TS 498, TS7046, TS 648,TS3357, TS 11372. Regulation Regarding Buildings to be Built in Earthquake Zones-2007
PURLIN STEEL CONSTRUCTION:
Material: Roof and Front: Erdemir quality no S350GD + Z (~ St 52), Erdemir quality no. 1335 quality standard DIN EN 10147-00. Building steel galvanized by zinc coating. Column: St37 material,
Production: Galvanized C / U sectioned cold formed profile compatible to JIT production system in TS EN 10162 standards.
Juncture components : Clinch nut, galvanized bolt, nut DIN 960-961,DIN 935-F,8.8
|